Sekumatic_FDR_Produktpalette

Sekumatic™ FDR

The aldehyde-free and efficient liquid for the chemo-thermal reprocessing in bed and cart decontamination systems. With unique active agent Glucoprotamin®. Suitable also for the chemo-thermal bedpan disinfection as well as for disinfection of respirator protection masks in washer-extractors and RDGs.

Produkteinzelheiten

The aldehyde-free and efficient liquid for the chemo-thermal reprocessing in bed and cart decontamination systems.

  • Secure disinfection
  • Effective cleaning
  • Gute Materialverträglichkeit
Unsere Leistung Ihr Nutzen
Aldehyde-free with unique active agent Glucoprotamin

Secure disinfection at 60°C, user-friendly formulation without aldehyde

Low in surfactants, pH-neutral Particularly low in foam, very good material compatibility, high cleaning performance

Optimally matched formulation components

Meets the requirements of “AK-BWA”
Certified by DEDEKRA EXAM (Testing institute for Respirator Protection) Safe and material-friendly disinfection of respiratory protective devices
High safety of use by automated dosing Precise dosing. No product contact by the user

When used in cleaning and disinfection devices (RDG) in the medical area, we recommend using a concentration of 10ml/l at 60°C and a contact time of at least 5 minutes. Observe the system manufacturer's instructions.

Recommended concentrations for use in bed and container washers are 5-10ml/l at 60°C and 90-120 seconds contact time.

When using in washer-extractors and RDGs for cleaning and disinfection of respirator protection masks, it is recommended that dosing of Sekumatic FDR be done above a temperature of 60°C. Observe the system manufacturer's instructions.

 

einsatztabelle_sekumatic_fdr_052015

Composition

Nicotinic surfactants, alcoholic solvents, sequestrants, corrosion inhibitors

100g contains as agents:

2.0 g glucoprotamine, 2.0 g poly(oxy-1, 2-ethandiyl), alpha-[2-(didecylmethyl-ammonio) ethyl]-omega-hydroxy-, propanoate (salt), 0.75 g benzalconium chloride

 

Use (after commencement) Shelf life
 
In container
 
until the printed expiration date

1
Please note the following to ensure the correct storage of environmental hygiene and instrument disinfectants: The original containers (canisters, buckets or bottles) with the disinfectant concentrate (or powder) should be stored at temperatures below 25°C and kept dry and clean. A brief period below or above the given storage temperature (e.g. during transport) will not diminish the effectiveness.
The containers are to be sealed tightly after each use. Please also take care that the concentrate remaining in the container is not contaminated when preparing the application solution.


Chemical- physical data
Density 20 °C 1.03 g / ml
pH value* (concentrate) 20 °C ca. 5.5
pH-value* (liquid, 5-10ml/l in DM-water) 20 °C 6 – 8

* pH-value measurements under operating conditions always by using pH-meter with temperature compensation.

 

pikto_instrumente_maschinellDesinfektionsmittel für Medizinprodukte
0297


 

Biozidprodukte vorsichtig verwenden. Vor Gebrauch stets Etikett und Produktinformationen lesen.

 

 

Ordering Information

Ordering information can be found in the product data sheet in the below download area of the page and in our product catalog.

SEHEN SIE SICH ANDERE PRODUKTE ZUR DESINFEKTION UND REINIGUNG VON INSTRUMENTEN AN

Ähnliche Angebote sehen Sie hier:

Dies ist ein Karussell. Nutzen Sie die Schaltflächen Weiter und Zurück, um zu navigieren, oder springen Sie mit den Folien-Punkten zu einer Folie.

DOWNLOADS

Weitere Informationen zu Produktdetails, Verpackungsgrößen und allen relevanten Bestellcodes finden Sie in der Produktbroschüre, die Sie nachstehend herunterladen können.

Healthcarereceptionarea550x310

ARBEITEN SIE MIT UNS ZUSAMMEN

Ecolab Healthcare kann mit Ihnen gemeinsam daran arbeiten Ihre Effizienz zu erhöhen, Ihre Ergebnisse zu verbessern und Krankenhausinfektionen (HAI) zu reduzieren.